Model Code |
AERIS-MB |
||||
Block Code |
AERIS-BG096 |
AERIS-B4830 |
AERIS-BG384 |
AERIS-BD048 |
AERIS-B4076 |
Sample Capacity |
96X0.2ml |
48x0.2ml |
384 wells |
48x0.2ml |
4 slides in situ |
Application Consumables |
0.2ml tubes |
0.2ml tubes |
384-well microplates |
0.2ml tubes |
4 slides in situ |
Max. Heating rate |
4.0ºC/sec |
2.8ºC/sec |
2.8ºC/sec |
4.0ºC/sec |
1.8ºC/sec |
Max. Cooling rate |
4.0ºC/sec |
2.8ºC/sec |
2.8ºC/sec |
4.0ºC/sec |
1.8ºC/sec |
Gradient Capability |
Yes |
- |
Yes |
- |
- |
Gradient Range |
30-105°C |
- |
30-105°C |
- |
- |
Maximum Gradient |
1-30°Cmode |
- |
1-30°C |
- |
- |
Temperature Control Mode |
Tube or Block |
||||
Temperature Range |
4-105ºC |
||||
Over-temperature Cut-Out |
Yes |
||||
Number of Programs |
Up to 250 programs, unlimited with USB flash drive |
||||
Maximum Hold Time |
59mins and 59secs |
||||
Temperature Accuracy |
≤±0.1ºC below 50ºC |
||||
Temperature Uniformity |
≤±0.2ºC |
||||
PCR Volume Range |
10-100 μl |
||||
Tm Calculator |
Auto |
||||
Extensive Experiment Application |
Option setting for time up/down is between 0-9m59s, which is suitable for long PCR Temperature when up/down is between 0.1ºC to 9.9ºC, it is suitable for Touchdown PCR |
||||
Auto Re-start On Power Failure |
Yes |
||||
Connection to PC Control |
Yes |
||||
Software |
AerisLine™ |
||||
Pre-Run Sample Cooling |
Yes, 4ºC |
||||
Language |
English, Chinese, Spanish |
||||
USB |
Yes |
||||
Display |
6.5“Color LCD Touch Screen |
||||
Dimensions |
306x386x295mm(12“x15“x11.6“) |
||||
Weight |
10kg |
||||
Power |
100-240V 50-60Hz |
Model Code |
AERIS-MB |
||||
Block Code |
AERIS-BG096 |
AERIS-B4830 |
AERIS-BG384 |
AERIS-BD048 |
AERIS-B4076 |
Sample Capacity |
96X0.2ml |
48x0.2ml |
384 wells |
48x0.2ml |
4 slides in situ |
Application Consumables |
0.2ml tubes |
0.2ml tubes |
384-well microplates |
0.2ml tubes |
4 slides in situ |
Max. Heating rate |
4.0ºC/sec |
2.8ºC/sec |
2.8ºC/sec |
4.0ºC/sec |
1.8ºC/sec |
Max. Cooling rate |
4.0ºC/sec |
2.8ºC/sec |
2.8ºC/sec |
4.0ºC/sec |
1.8ºC/sec |
Gradient Capability |
Yes |
- |
Yes |
- |
- |
Gradient Range |
30-105°C |
- |
30-105°C |
- |
- |
Maximum Gradient |
1-30°Cmode |
- |
1-30°C |
- |
- |
Temperature Control Mode |
Tube or Block |
||||
Temperature Range |
4-105ºC |
||||
Over-temperature Cut-Out |
Yes |
||||
Number of Programs |
Up to 250 programs, unlimited with USB flash drive |
||||
Maximum Hold Time |
59mins and 59secs |
||||
Temperature Accuracy |
≤±0.1ºC below 50ºC |
||||
Temperature Uniformity |
≤±0.2ºC |
||||
PCR Volume Range |
10-100 μl |
||||
Tm Calculator |
Auto |
||||
Extensive Experiment Application |
Option setting for time up/down is between 0-9m59s, which is suitable for long PCR Temperature when up/down is between 0.1ºC to 9.9ºC, it is suitable for Touchdown PCR |
||||
Auto Re-start On Power Failure |
Yes |
||||
Connection to PC Control |
Yes |
||||
Software |
AerisLine™ |
||||
Pre-Run Sample Cooling |
Yes, 4ºC |
||||
Language |
English, Chinese, Spanish |
||||
USB |
Yes |
||||
Display |
6.5“Color LCD Touch Screen |
||||
Dimensions |
306x386x295mm(12“x15“x11.6“) |
||||
Weight |
10kg |
||||
Power |
100-240V 50-60Hz |